Show simple item record

dc.contributor.author
Gilgen-Ammann, Rahel
dc.contributor.author
Roos, Lilian
dc.contributor.author
Wyss, Thomas
dc.contributor.author
Veenstra, Bertil J.
dc.contributor.author
Delves, Simon K.
dc.contributor.author
Beeler, Nadja
dc.contributor.author
Buller, Mark J.
dc.contributor.author
Friedl, Karl E.
dc.date.accessioned
2021-11-30T12:38:50Z
dc.date.available
2021-11-11T11:06:51Z
dc.date.available
2021-11-11T13:32:07Z
dc.date.available
2021-11-30T12:38:50Z
dc.date.issued
2021-08-27
dc.identifier.issn
0967-3334
dc.identifier.issn
1361-6579
dc.identifier.other
10.1088/1361-6579/ac19f9
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/514773
dc.identifier.doi
10.3929/ethz-b-000514773
dc.description.abstract
Objectives.To investigate the validity of different devices and algorithms used in military organizations worldwide to assess physical activity energy expenditure (PAEE) and heart rate (HR) among soldiers. Design. Device validation study. Methods. Twenty-three male participants serving their mandatory military service accomplished, firstly, nine different military specific activities indoors, and secondly, a normal military routine outdoors. Participants wore simultaneously an ActiHeart, Everion, MetaMax 3B, Garmin Fenix 3, Hidalgo EQ02, and PADIS 2.0 system. The PAEE and HR data of each system were compared to the criterion measures MetaMax 3B and Hidalgo EQ02, respectively. Results. Overall, the recorded systematic errors in PAEE estimation ranged from 0.1 (±1.8) kcal.min−1 to −1.7 (±1.8) kcal.min−1 for the systems PADIS 2.0 and Hidalgo EQ02 running the Royal Dutch Army algorithm, respectively, and in the HR assessment ranged from −0.1 (±2.1) b.min−1 to 0.8 (±3.0) b.min−1 for the PADIS 2.0 and ActiHeart systems, respectively. The mean absolute percentage error (MAPE) in PAEE estimation ranged from 29.9% to 75.1%, with only the Everion system showing an overall MAPE <30%, but all investigated devices reported overall MAPE <1.4% in the HR assessment. Conclusions. The present study demonstrated poor to moderate validity in terms of PAEE estimation, but excellent validity in all investigated devices in terms of HR assessment. Overall, the Everion performed among the best in both parameters and with a device placement on the upper arm, the Everion system is particularly useful during military service, as it does not interfere with other relevant equipment.
en_US
dc.format
application/pdf
en_US
dc.language.iso
en
en_US
dc.publisher
IOP Publishing
en_US
dc.rights.uri
http://creativecommons.org/licenses/by/4.0/
dc.subject
Physiological monitoring
en_US
dc.subject
Military personnel
en_US
dc.subject
Wearable electronic devices
en_US
dc.subject
Fitness trackers
en_US
dc.title
Validation of ambulatory monitoring devices to measure energy expenditure and heart rate in a military setting
en_US
dc.type
Journal Article
dc.rights.license
Creative Commons Attribution 4.0 International
ethz.journal.title
Physiological Measurement
ethz.journal.volume
42
en_US
ethz.journal.issue
8
en_US
ethz.journal.abbreviated
Physiol. Meas.
ethz.pages.start
085008
en_US
ethz.size
9 p.
en_US
ethz.version.deposit
publishedVersion
en_US
ethz.publication.place
Bristol
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02045 - Dep. Geistes-, Sozial- u. Staatswiss. / Dep. of Humanities, Social and Pol.Sc.::02527 - Institut für Verhaltenswissenschaften / Institute of Behavioral Sciences::09590 - Kapur, Manu / Kapur, Manu
en_US
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02045 - Dep. Geistes-, Sozial- u. Staatswiss. / Dep. of Humanities, Social and Pol.Sc.::02527 - Institut für Verhaltenswissenschaften / Institute of Behavioral Sciences::09590 - Kapur, Manu / Kapur, Manu
en_US
ethz.date.deposited
2021-11-11T11:06:57Z
ethz.source
FORM
ethz.eth
yes
en_US
ethz.availability
Open access
en_US
ethz.rosetta.installDate
2021-11-11T13:32:15Z
ethz.rosetta.lastUpdated
2023-02-06T23:22:48Z
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&amp;rft_val_fmt=info:ofi/fmt:kev:mtx:journal&amp;rft.atitle=Validation%20of%20ambulatory%20monitoring%20devices%20to%20measure%20energy%20expenditure%20and%20heart%20rate%20in%20a%20military%20setting&amp;rft.jtitle=Physiological%20Measurement&amp;rft.date=2021-08-27&amp;rft.volume=42&amp;rft.issue=8&amp;rft.spage=085008&amp;rft.issn=0967-3334&amp;1361-6579&amp;rft.au=Gilgen-Ammann,%20Rahel&amp;Roos,%20Lilian&amp;Wyss,%20Thomas&amp;Veenstra,%20Bertil%20J.&amp;Delves,%20Simon%20K.&amp;rft.genre=article&amp;rft_id=info:doi/10.1088/1361-6579/ac19f9&amp;
 Search print copy at ETH Library

Files in this item

Thumbnail

Publication type

Show simple item record