Abstract
The physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located very close to the LHC beam line, at a radial distance of about 1 cm from the beam pipe, and at 14.4 m from the CMS interaction point, covering the pseudorapidity range of -6.6 < eta < - 5.2. It was designed to withstand high ambient radiation and strong magnetic fields. The performance of the detector in measurements of forward energy density, jets, and processes characterized by rapidity gaps, is reviewed using data collected in proton and nuclear collisions at the LHC. Show more
Permanent link
https://doi.org/10.3929/ethz-b-000495176Publication status
publishedJournal / series
Journal of InstrumentationVolume
Pages / Article No.
Publisher
The Electrochemical SocietySubject
Calorimeters; Cherenkov detectors; Large detector systems for particle and astropartide physicsOrganisational unit
03593 - Dissertori, Günther / Dissertori, Günther
03904 - Wallny, Rainer / Wallny, Rainer
08803 - Grab, Christoph (Tit.Prof.)
09720 - de Cosa, Annapaola / de Cosa, Annapaola
More
Show all metadata
ETH Bibliography
yes
Altmetrics