Diagnosis and Treatment Strategies of Outflow Graft Obstruction in the Fully Magnetically Levitated Continuous-Flow centrifugal Left Ventricular Assist Device: A Multicenter Case Series
dc.contributor.author
Wert, Leonhard
dc.contributor.author
Kaufmann, Friedrich
dc.contributor.author
Solowjowa, Natalia
dc.contributor.author
Dreysse, Stephan
dc.contributor.author
Zimpfer, Daniel
dc.contributor.author
Falk, Volkmar
dc.contributor.author
Potapov, Evgenij V.
dc.contributor.author
Mulzer, Johanna
dc.date.accessioned
2021-01-11T08:51:51Z
dc.date.available
2021-01-11T03:53:27Z
dc.date.available
2021-01-11T08:51:51Z
dc.date.issued
2021-01
dc.identifier.issn
1058-2916
dc.identifier.issn
1538-943X
dc.identifier.other
10.1097/MAT.0000000000001213
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/460918
dc.description.abstract
Outflow graft obstruction in left ventricular assist devices (LVADs) is a rare complication whose clinical presentation may be subtle. We present six cases of outflow graft obstruction in patients on HeartMate 3 LVAD detected between 648 and 1,222 days on support. Detection principles are described and treatment strategies discussed. Three patients were successfully managed with stents, one underwent surgical revision, one patient died despite emergency treatment, and the last patient without symptoms was listed for heart transplantation. © ASAIO 2020
en_US
dc.language.iso
en
en_US
dc.publisher
Lippincott Williams & Wilkins
en_US
dc.subject
left ventricular assist device
en_US
dc.subject
HeartMate 3
en_US
dc.subject
outflow graft obstruction
en_US
dc.title
Diagnosis and Treatment Strategies of Outflow Graft Obstruction in the Fully Magnetically Levitated Continuous-Flow centrifugal Left Ventricular Assist Device: A Multicenter Case Series
en_US
dc.type
Journal Article
ethz.journal.title
ASAIO Journal
ethz.journal.volume
67
en_US
ethz.journal.issue
1
en_US
ethz.journal.abbreviated
ASAIO J
ethz.pages.start
e52
en_US
ethz.pages.end
e54
en_US
ethz.identifier.wos
ethz.identifier.scopus
ethz.publication.place
Hagerstown, MD
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::02540 - Institut für Translationale Medizin / Institute of Translational Medicine::09667 - Falk, Volkmar / Falk, Volkmar
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::02540 - Institut für Translationale Medizin / Institute of Translational Medicine::09667 - Falk, Volkmar / Falk, Volkmar
ethz.date.deposited
2021-01-11T03:53:30Z
ethz.source
SCOPUS
ethz.eth
yes
en_US
ethz.availability
Metadata only
en_US
ethz.rosetta.installDate
2021-01-11T08:51:59Z
ethz.rosetta.lastUpdated
2024-02-02T12:48:39Z
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Diagnosis%20and%20Treatment%20Strategies%20of%20Outflow%20Graft%20Obstruction%20in%20the%20Fully%20Magnetically%20Levitated%20Continuous-Flow%20centrifugal%20Left%20Vent&rft.jtitle=ASAIO%20Journal&rft.date=2021-01&rft.volume=67&rft.issue=1&rft.spage=e52&rft.epage=e54&rft.issn=1058-2916&1538-943X&rft.au=Wert,%20Leonhard&Kaufmann,%20Friedrich&Solowjowa,%20Natalia&Dreysse,%20Stephan&Zimpfer,%20Daniel&rft.genre=article&rft_id=info:doi/10.1097/MAT.0000000000001213&
Files in this item
Files | Size | Format | Open in viewer |
---|---|---|---|
There are no files associated with this item. |
Publication type
-
Journal Article [131554]