Show simple item record

dc.contributor.author
Kohler, Thomas
dc.contributor.author
Beyeler, M.
dc.contributor.author
Webster, Duncan
dc.contributor.author
Müller, Ralph
dc.date.accessioned
2020-04-28T12:50:47Z
dc.date.available
2020-04-28T12:45:27Z
dc.date.available
2020-04-28T12:50:47Z
dc.date.issued
2005-11
dc.identifier.issn
0171-967X
dc.identifier.issn
1432-0827
dc.identifier.other
10.1007/s00223-005-0039-2
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/412111
dc.identifier.doi
10.3929/ethz-b-000412111
dc.format
application/pdf
dc.language.iso
en
en_US
dc.publisher
Springer
en_US
dc.rights.uri
http://rightsstatements.org/page/InC-NC/1.0/
dc.subject
Microcomputed tomography (μCT)
en_US
dc.subject
Inbred mouse strain
en_US
dc.subject
Bone density
en_US
dc.subject
Bone architecture/structure
en_US
dc.subject
Reproducibility
en_US
dc.subject
Resolution dependence
en_US
dc.title
Compartmental bone morphometry in the mouse femur: Reproducibility and resolution dependence of microtomographic measurements
en_US
dc.type
Journal Article
dc.rights.license
In Copyright - Non-Commercial Use Permitted
dc.date.published
2005-11-04
ethz.journal.title
Calcified Tissue International
ethz.journal.volume
77
en_US
ethz.journal.issue
5
en_US
ethz.journal.abbreviated
Calcif Tissue Int
ethz.pages.start
281
en_US
ethz.pages.end
290
en_US
ethz.version.deposit
publishedVersion
ethz.notes
It was possible to publish this article open access thanks to a Swiss National Licence with the publisher
ethz.identifier.wos
ethz.publication.place
Berlin
en_US
ethz.publication.status
published
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::02518 - Institut für Biomechanik / Institute for Biomechanics
en_US
ethz.leitzahl
03656 - Bösiger, Peter
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::02518 - Institut für Biomechanik / Institute for Biomechanics::03565 - Müller, Ralph / Müller, Ralph
en_US
ethz.leitzahl.certified
03656 - Bösiger, Peter
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::02518 - Institut für Biomechanik / Institute for Biomechanics::03565 - Müller, Ralph / Müller, Ralph
ethz.date.deposited
2017-06-09T09:41:51Z
ethz.source
ECIT
ethz.identifier.importid
imp593650f81fefd90534
ethz.identifier.importid
imp59364db50e7b375502
ethz.ecitpid
pub:113185
ethz.ecitpid
pub:51246
ethz.eth
yes
en_US
ethz.availability
Open access
ethz.rosetta.installDate
2020-04-28T12:45:40Z
ethz.rosetta.lastUpdated
2021-02-15T10:45:23Z
ethz.rosetta.versionExported
true
dc.identifier.olduri
http://hdl.handle.net/20.500.11850/163608
dc.identifier.olduri
http://hdl.handle.net/20.500.11850/30952
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Compartmental%20bone%20morphometry%20in%20the%20mouse%20femur:%20Reproducibility%20and%20resolution%20dependence%20of%20microtomographic%20measurements&rft.jtitle=Calcified%20Tissue%20International&rft.date=2005-11&rft.volume=77&rft.issue=5&rft.spage=281&rft.epage=290&rft.issn=0171-967X&1432-0827&rft.au=Kohler,%20Thomas&Beyeler,%20M.&Webster,%20Duncan&M%C3%BCller,%20Ralph&rft.genre=article&rft_id=info:doi/10.1007/s00223-005-0039-2&
 Search print copy at ETH Library

Files in this item

Thumbnail

Publication type

Show simple item record