dc.description.abstract
Purpose In diffusion MRI, the actual b‐value played out on the scanner may deviate from the nominal value due to magnetic field imperfections. A simple image‐based correction method for this problem is presented. Methods The apparent diffusion constant (ADC) of a water phantom was measured voxel‐wise along 64 diffusion directions at b = 1000 s/mm2. The true diffusion constant of water was estimated, considering the phantom temperature. A voxel‐wise correction factor, providing an effective b‐value including any magnetic field deviations, was determined for each diffusion direction by relating the measured ADC to the true diffusion constant. To test the method, the measured b‐value map was used to calculate the corrected voxel‐wise ADC for additionally acquired diffusion data sets on the same water phantom and data sets acquired on a small water phantom at three different positions. Diffusion tensor was estimated by applying the measured b‐value map to phantom and in vivo data sets. Results The b‐value‐corrected ADC maps of the phantom showed the expected spatial uniformity as well as a marked improvement in consistency across diffusion directions. The b‐value correction for the brain data resulted in a 5.8% and 5.5% decrease in mean diffusivity and angular differences of the primary diffusion direction of 2.71° and 0.73° inside gray and white matter, respectively. Conclusion The actual b‐value deviates significantly from its nominal setting, leading to a spatially variable error in the common diffusion outcome measures. The suggested method measures and corrects these artifacts.
en_US
dc.format
application/pdf
en_US
dc.language.iso
en
en_US
dc.publisher
Wiley
en_US
dc.rights.uri
http://creativecommons.org/licenses/by/4.0/
dc.subject
b-value
en_US
dc.subject
diffusion gradient
en_US
dc.subject
diffusion MRI
en_US
dc.subject
diffusion tensor
en_US
dc.subject
gradient nonlinearity
en_US
dc.title
A comprehensive approach for correcting voxel-wise b-value errors in diffusion MRI
en_US
dc.type
Journal Article
dc.rights.license
Creative Commons Attribution 4.0 International
dc.date.published
2019-12-16
ethz.journal.title
Magnetic Resonance in Medicine
ethz.journal.volume
83
en_US
ethz.journal.issue
6
en_US
ethz.journal.abbreviated
Magn Reson Med
ethz.pages.start
2173
en_US
ethz.pages.end
2184
en_US
ethz.version.deposit
publishedVersion
en_US
ethz.identifier.wos
ethz.identifier.scopus
ethz.publication.place
Hoboken, NJ
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02140 - Dep. Inf.technologie und Elektrotechnik / Dep. of Inform.Technol. Electrical Eng.::02631 - Institut für Biomedizinische Technik / Institute for Biomedical Engineering::03628 - Prüssmann, Klaas P. / Prüssmann, Klaas P.
en_US
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02140 - Dep. Inf.technologie und Elektrotechnik / Dep. of Inform.Technol. Electrical Eng.::02631 - Institut für Biomedizinische Technik / Institute for Biomedical Engineering::03628 - Prüssmann, Klaas P. / Prüssmann, Klaas P.
ethz.relation.isVariantFormOf
10.3929/ethz-b-000409242
ethz.date.deposited
2019-12-27T03:53:26Z
ethz.source
WOS
ethz.eth
yes
en_US
ethz.availability
Open access
en_US
ethz.rosetta.installDate
2020-03-06T11:43:40Z
ethz.rosetta.lastUpdated
2022-03-29T01:14:59Z
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=A%20comprehensive%20approach%20for%20correcting%20voxel-wise%20b-value%20errors%20in%20diffusion%20MRI&rft.jtitle=Magnetic%20Resonance%20in%20Medicine&rft.date=2020-06&rft.volume=83&rft.issue=6&rft.spage=2173&rft.epage=2184&rft.issn=0740-3194&1522-2594&rft.au=Lee,%20Yoojin&Kettinger,%20Adam%20O.&Wilm,%20Bertram%20J.&Deichmann,%20Ralf&Weiskopf,%20Nikolaus&rft.genre=article&rft_id=info:doi/10.1002/mrm.28078&
 Search print copy at ETH Library

Files in this item

Thumbnail

Publication type

Show simple item record