A method for correcting breathing-induced field fluctuations in T2*-weighted spinal cord imaging using a respiratory trace
dc.contributor.author
Vannesjo, S. Johanna
dc.contributor.author
Clare, Stuart
dc.contributor.author
Kasper, Lars
dc.contributor.author
Tracey, Irene
dc.contributor.author
Miller, Karla L.
dc.date.accessioned
2019-04-02T07:35:59Z
dc.date.available
2019-04-02T02:57:54Z
dc.date.available
2019-04-02T07:35:59Z
dc.date.issued
2019-06
dc.identifier.issn
0740-3194
dc.identifier.issn
1522-2594
dc.identifier.other
10.1002/mrm.27664
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/335375
dc.identifier.doi
10.3929/ethz-b-000335375
dc.description.abstract
Purpose
Spinal cord MRI at ultrahigh field is hampered by time‐varying magnetic fields associated with the breathing cycle, giving rise to ghosting artifacts in multi‐shot acquisitions. Here, we suggest a correction approach based on linking the signal from a respiratory bellows to field changes inside the spinal cord. The information is used to correct the data at the image reconstruction level.
Methods
The correction was demonstrated in the context of multi‐shot T2*‐weighted imaging of the cervical spinal cord at 7T. A respiratory trace was acquired during a high‐resolution multi‐echo gradient‐echo sequence, used for structural imaging and quantitative T2* mapping, and a multi‐shot EPI time series, as would be suitable for fMRI. The coupling between the trace and the breathing‐induced fields was determined by a short calibration scan in each individual. Images were reconstructed with and without trace‐based correction.
Results
In the multi‐echo acquisition, breathing‐induced fields caused severe ghosting in images with long TE, which led to a systematic underestimation of T2* in the spinal cord. The trace‐based correction reduced the ghosting and increased the estimated T2* values. Breathing‐related ghosting was also observed in the multi‐shot EPI images. The correction largely removed the ghosting, thereby improving the temporal signal‐to‐noise ratio of the time series.
Conclusions
Trace‐based retrospective correction of breathing‐induced field variations can reduce ghosting and improve quantitative metrics in multi‐shot structural and functional T2*‐weighted imaging of the spinal cord. The method is straightforward to implement and does not rely on sequence modifications or additional hardware beyond a respiratory bellows.
en_US
dc.format
application/pdf
en_US
dc.language.iso
en
en_US
dc.publisher
Wiley
en_US
dc.rights.uri
http://creativecommons.org/licenses/by/4.0/
dc.subject
7T MRI
en_US
dc.subject
breathing‐induced field fluctuations
en_US
dc.subject
multi‐shot EPI
en_US
dc.subject
spinal cord imaging
en_US
dc.subject
T2* mapping
en_US
dc.title
A method for correcting breathing-induced field fluctuations in T2*-weighted spinal cord imaging using a respiratory trace
en_US
dc.type
Journal Article
dc.rights.license
Creative Commons Attribution 4.0 International
dc.date.published
2019-02-08
ethz.journal.title
Magnetic Resonance in Medicine
ethz.journal.volume
81
en_US
ethz.journal.issue
6
en_US
ethz.journal.abbreviated
Magn Reson Med
ethz.pages.start
3745
en_US
ethz.pages.end
3753
en_US
ethz.version.deposit
publishedVersion
en_US
ethz.identifier.wos
ethz.identifier.scopus
ethz.publication.place
Hoboken, NJ
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02140 - Dep. Inf.technologie und Elektrotechnik / Dep. of Inform.Technol. Electrical Eng.::02631 - Institut für Biomedizinische Technik / Institute for Biomedical Engineering::03955 - Stephan, Klaas E. / Stephan, Klaas E.
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02140 - Dep. Inf.technologie und Elektrotechnik / Dep. of Inform.Technol. Electrical Eng.::02631 - Institut für Biomedizinische Technik / Institute for Biomedical Engineering::03955 - Stephan, Klaas E. / Stephan, Klaas E.
ethz.date.deposited
2019-04-02T02:57:54Z
ethz.source
SCOPUS
ethz.eth
yes
en_US
ethz.availability
Open access
en_US
ethz.rosetta.installDate
2019-04-02T07:36:29Z
ethz.rosetta.lastUpdated
2022-03-28T22:41:57Z
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=A%20method%20for%20correcting%20breathing-induced%20field%20fluctuations%20in%20T2*-weighted%20spinal%20cord%20imaging%20using%20a%20respiratory%20trace&rft.jtitle=Magnetic%20Resonance%20in%20Medicine&rft.date=2019-06&rft.volume=81&rft.issue=6&rft.spage=3745&rft.epage=3753&rft.issn=0740-3194&1522-2594&rft.au=Vannesjo,%20S.%20Johanna&Clare,%20Stuart&Kasper,%20Lars&Tracey,%20Irene&Miller,%20Karla%20L.&rft.genre=article&rft_id=info:doi/10.1002/mrm.27664&
Files in this item
Publication type
-
Journal Article [131676]