Single breath-hold 3D measurement of left atrial volume using compressed sensing cardiovascular magnetic resonance and a non-model-based reconstruction approach
dc.contributor.author
Vardoulis, Orestis
dc.contributor.author
Monney, Pierre
dc.contributor.author
Bermano, Amit
dc.contributor.author
Vaxman, Amir
dc.contributor.author
Gotsman, Craig
dc.contributor.author
Schwitter, Janine
dc.contributor.author
Stuber, Matthias
dc.contributor.author
Stergiopulos, Nikolaos
dc.contributor.author
Schwitter, Juerg
dc.date.accessioned
2019-03-25T13:30:08Z
dc.date.available
2019-03-22T09:51:36Z
dc.date.available
2019-03-25T13:30:08Z
dc.date.issued
2015
dc.identifier.issn
1097-6647
dc.identifier.issn
1532-429X
dc.identifier.other
10.1186/s12968-015-0147-8
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/333114
dc.identifier.doi
10.3929/ethz-b-000333114
dc.description.abstract
Background
Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration.
Aim
To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function.
Methods
A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes.
Results
Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of −4.73 ± 1.75 ml (−8.67 ± 3.54 %, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis “aligned” vs “not aligned” with the phantom long-axis yielded similar differences vs the reference volume (−4.87 ± 1.73 ml vs −4.45 ± 1.97 ml, p = 0.67) and short-axis “perpendicular” vs “not-perpendicular” with the LA long-axis (−4.72 ± 1.66 ml vs −4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of “slice orientation” and “reconstruction technique”, 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: −1.37 ± 1.35 ml, −2.38 ± 2.44 %, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of −2.66 ± 6.5 ml (3.0 % underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown.
Conclusions
The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
en_US
dc.format
application/pdf
en_US
dc.language.iso
en
en_US
dc.publisher
BioMed Central
en_US
dc.rights.uri
http://creativecommons.org/licenses/by/4.0/
dc.title
Single breath-hold 3D measurement of left atrial volume using compressed sensing cardiovascular magnetic resonance and a non-model-based reconstruction approach
en_US
dc.type
Journal Article
dc.rights.license
Creative Commons Attribution 4.0 International
dc.date.published
2015-06-11
ethz.journal.title
Journal of Cardiovascular Magnetic Resonance
ethz.journal.volume
17
en_US
ethz.journal.issue
1
en_US
ethz.journal.abbreviated
J Cardiovasc Magn Reson
ethz.pages.start
47
en_US
ethz.size
14 p.
en_US
ethz.version.deposit
publishedVersion
en_US
ethz.publication.place
London
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02150 - Dep. Informatik / Dep. of Computer Science::02659 - Institut für Visual Computing / Institute for Visual Computing::03420 - Gross, Markus / Gross, Markus
en_US
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02150 - Dep. Informatik / Dep. of Computer Science::02659 - Institut für Visual Computing / Institute for Visual Computing::03420 - Gross, Markus / Gross, Markus
en_US
ethz.date.deposited
2019-03-22T09:51:49Z
ethz.source
FORM
ethz.eth
yes
en_US
ethz.availability
Open access
en_US
ethz.rosetta.installDate
2019-03-25T13:30:20Z
ethz.rosetta.lastUpdated
2020-02-15T18:02:34Z
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Single%20breath-hold%203D%20measurement%20of%20left%20atrial%20volume%20using%20compressed%20sensing%20cardiovascular%20magnetic%20resonance%20and%20a%20non-model-based%&rft.jtitle=Journal%20of%20Cardiovascular%20Magnetic%20Resonance&rft.date=2015&rft.volume=17&rft.issue=1&rft.spage=47&rft.issn=1097-6647&1532-429X&rft.au=Vardoulis,%20Orestis&Monney,%20Pierre&Bermano,%20Amit&Vaxman,%20Amir&Gotsman,%20Craig&rft.genre=article&rft_id=info:doi/10.1186/s12968-015-0147-8&
Dateien zu diesem Eintrag
Publikationstyp
-
Journal Article [131991]