“Good Practice” Guide for Managing Induced Seismicity in Deep Geothermal Energy Projects in Switzerland
Open access
Datum
2017-10Typ
- Report
ETH Bibliographie
yes
Altmetrics
Abstract
The proposed framework is currently customized to Switzerland and can be adapted to other regions or types of geo-energy applications.
Deep geothermal systems can induce potentially damaging seismicity. How this seismicity should be addressed depends on the geothermal system itself, its operational characteristics, the geological context, the exposed buildings, infrastructure and populations, as well as social concern. After a presentation of the natural and induced seismicity in Switzerland, this report promotes the use of the initial screening tool, called Geothermal Risk of Induced seismicity Diagnosis (GRID, Trutnevyte & Wiemer, 2017), for estimating to what extent induced seismicity is of concern for a specific project. A framework for tailor-made risk governance measures to be taken through the different phases of a project is then recommended, including hazard and risk assessment, seismic monitoring, traffic light systems, seismic reflection data interpretation, and public and stakeholder engagement. Mehr anzeigen
Persistenter Link
https://doi.org/10.3929/ethz-b-000254161Publikationsstatus
publishedExterne Links
Verlag
SED, Swiss Seismological Service at ETH ZürichThema
risk governance; geothermal energy; induced seismicityOrganisationseinheit
02818 - Schweiz. Erdbebendienst (SED) / Swiss Seismological Service (SED)
Zugehörige Publikationen und Daten
Is supplemented by: https://doi.org/10.3929/ethz-b-000429398
Is previous version of: https://doi.org/10.3929/ethz-b-000453228
ETH Bibliographie
yes
Altmetrics